Mercaptopurine Tablets
Failed USP Dissolution Test Requirements: The recalled lots do not meet the specification for dissolution.
530 recalls, newest first
Failed USP Dissolution Test Requirements: The recalled lots do not meet the specification for dissolution.
Failed USP Content Uniformity Requirements: OOS result reported on retained samples.
Impurities/Degradation Products: Out of specification results for Related Compound during routine stability testing.
Labeling: Label Mix-up: The product is being recalled because active ingredient in the Drug Facts box incorrectly states "Active Ingredients per dose" Senna Leaf powder 140 mg. It should correctly be stated as "Active ingredient (in each capsule)" Senna Leaf Powder 140 mg.It should correctly be stated as Active ingredient (in each capsule) Senna Leaf Powder 140 mg.
The affected lots of Carboplatin Injection, Cytarabine Injection, Methotrexate Injection, USP, and Paclitaxel Injection are being recalled due to visible particles embedded in the glass located at the neck of the vial. There may be the potential for product to come into contact with the embedded particles and the particles may become dislodged into the solution.
The affected lots of Carboplatin Injection, Cytarabine Injection, Methotrexate Injection, USP, and Paclitaxel Injection are being recalled due to visible particles embedded in the glass located at the neck of the vial. There may be the potential for product to come into contact with the embedded particles and the particles may become dislodged into the solution.
The affected lots of Carboplatin Injection, Cytarabine Injection, Methotrexate Injection, USP, and Paclitaxel Injection are being recalled due to visible particles embedded in the glass located at the neck of the vial. There may be the potential for product to come into contact with the embedded particles and the particles may become dislodged into the solution.
The affected lots of Carboplatin Injection, Cytarabine Injection, Methotrexate Injection, USP, and Paclitaxel Injection are beig recalled due to visible particles embedded in the glass located at the neck of the vial. There may be the potential for product to come into contact with the embedded particles and the particles may become dislodged into the solution.
Presence of Particulate Matter
CGMP Deviations: Shipment of product not approved for release.
CGMP Deviations; no identity or purity testing on incoming oxygen gas, and lack of documentation
Subpotent (Single Ingredient) Drug: This product is being recalled because of sub-potency of the sennosides.
Labeling: Label Mix-up: The affected units were labeled incorrectly describing the product as "ointment" instead of "solution."
Microbial contamination of Non Sterile Product; contamination with Burkholderia cepacia (manufacturer)
Microbial contamination of Non Sterile Product; contamination with Burkholderia cepacia (manufacturer)
Microbial Contamination of Non-Sterile Products; The affected lots were found to be contaminated with bacterium, Burkholderia cepacia complex.
Microbial Contamination of Non-Sterile Products; The affected lots were found to be contaminated with bacterium, Burkholderia cepacia complex.
Chemical Contamination: This product is being recalled because trace amounts of a plasticizer (Di-Octyl Phthalate) may be present in the product.
Impurities/Degradation Products: High Out of Specification levels for carbostyril, a known degradation product of diazepam.
Impurities/Degradation Products: High Out-of-specification results were obtained for both known and unknown impurities.
Labeling: Label Mix-up: Pitocin storage conditions should be labeled, "Store between 20¿ to 25¿C (68¿ to 77¿F)". Pitocin lot 225867 and part of Pitocin lot 231423 were labeled, "Store between 20¿ to 25¿C (28¿ to 77¿F)".
Labeling; Correct labeled product miscart/mispack: Some Physician sample cartons were incorrectly labeled as Kombiglyze XR 2.5mg/1000mg on the external package carton, whereas the contents were Kombiglyze XR 5 mg/500 mg blister packaged tablets. The individual blister units are labeled correctly.
Labeling; Correct labeled product miscart/mispack: Some Physician sample cartons were incorrectly labeled as Kombiglyze XR 2.5mg/1000mg on the external package carton, whereas the contents were Kombiglyze XR 5 mg/500 mg blister packaged tablets. The individual blister units are labeled correctly.
Adulterated Presence of Foreign Tablets: Trizivir 300/150/300 mg tables, Lot 0ZP5128 may incorrectly contain Lexiva 700 mg tablets.
GMP deviation; Sr-82 levels exceeded alert limit specification