methylprednisolone tablets
Labeling: Not Elsewhere Classified. Incorrect orientation of the blister foil applied to the blister cavities, which results in incorrect dosing information when following the directions on the foil.
Class III — Low risk. Unlikely to cause harm, but violates FDA regulations.
Failed pH Specification: A pH result of 2.9 was obtained at the 9 month stability test interval at 25C/60%RH. The registered specification for pH is 3.0 - 7.0
Cause type: Failed specification
A physical or chemical test other than potency, dissolution, impurity or stability failed - pH, viscosity, appearance, tablet integrity, fill volume. A product outside its own specification may not perform as designed, even if the active ingredient is present. All failed specification recalls.
Depo-Medrol (methylprednisolone acetate injectable suspension USP), 40 mg/ mL, 1 mL Single-Dose Vial, Rx only, Distributed by Pharmacia & Upjohn Co Division of Pfizer Inc, New York NY 10017 NDC 0009-3073-03 DEPO-MEDROL methylprednisolone acetate Injectable Suspension USP, 40 mg per mL, 1 mL Single-Dose Vial, Rx ONLY, Distributed by Pharmacia & Upjohn Co Division of Pfizer Inc, New York NY 10017, NOVAPLUS is a registered trademark of Novation, LLC NDC 0009-3073-23
Compare with the code on your package — it is the most precise check available.
Drug: Methylprednisolone
From the FDA NDC directory, for the product code this recall names. Compare with the label on your package.
| Product | Strength | Form & route | Labeler | Type |
|---|---|---|---|---|
| Depo-Medrol methylprednisolone acetate NDC 00009-3073 |
40 mg/mL | Injection, Suspension Intralesional|intramuscular|intrasynovial|soft Tissue |
Pharmacia & Upjohn Company LLC | Rx |
Low risk, still worth a check. Class III means the product is unlikely to cause harm but breaks an FDA rule (often labeling). If your lot matches, your pharmacy will normally swap it; there is no need for alarm. This recall is now terminated, which means the firm has finished removing the affected product; anything on pharmacy shelves today should be unaffected.
Labeling: Not Elsewhere Classified. Incorrect orientation of the blister foil applied to the blister cavities, which results in incorrect dosing information when following the directions on the foil.
Presence of Particulate Matter: Potential for black particulates in the drug product.
Failed Dissolution Specifications
Labeling: Not Elsewhere Classified; A typographical error was observed in the NDC number on the preprinted Individual Folding Cartons (secondary packaging only). Incorrect NDC Number 70121-1573-1; Correct NDC Number 70121-1574-1.
Lack of sterility assurance
Lack of Assurance of Sterility
Lack of Assurance of Sterility.
Lack of Assurance of Sterility.
Subpotent drug