Phenylephrine Hydrochloride Injectable Solution
cGMP deviations.
Class II — Moderate risk. May cause temporary or reversible harm; serious harm unlikely.
Lack of Assurance of Sterility: a recent FDA inspection at the manufacturing firm raised concerns that product sterility may be compromised.
Cause type: Sterility / contamination
A product that must be sterile could not be assured sterile, or was contaminated. A top reason for injectables, eye drops and IV products - loss of sterility assurance can lead to serious infections. All sterility / contamination recalls.
Phenylephrine HCI Injection, USP, 10mg/mL, packaged in a) 5 mL Vial, 50 mg/5 mL (NDC 66758-016-03), 25 x 5 mL Vials per carton (NDC 66758-016-04) and b) 10 mL Vials, 100 mg/10 mL (NDC 66758-017-01), Rx only, Manufactured for: Sandoz Inc., Princeton, NJ 08540.
Compare with the code on your package — it is the most precise check available.
Drug: Phenylephrine
Check, then ask. Class II means harm is possible but usually temporary or reversible. Find the lot number on your package; if it matches, ask your pharmacist about a replacement. Do not simply stop a prescribed medication on your own - the gap can be riskier than the recall. This recall is now terminated, which means the firm has finished removing the affected product; anything on pharmacy shelves today should be unaffected.
cGMP deviations.
Incorrect Product Formulation
CGMP Deviations
Sub-Potent Drug: Subpotent assay results during stability testing.
Lack of Assurance of Sterility: Leaking/damaged syringes.
Labeling: Incorrect or Missing Lot and/or Exp Date
cGMP deviations: Temperature excursion during transportation.
Temperature Abuse
Labeling: Label Mix-Up; Some vials of Cefazolin for Injection, USP 1 gram were incorrectly labeled as penicillin G potassium for Injection, USP, 20 million Unit
Free recall alerts
Tell us what you take. When FDA posts a recall announcement or classifies a recall for one of your medications, we email you in plain English, with what to check. No account needed.