POTASSIUM CHLORIDE Inj.
Labeling: Label Error on Declared Strength. Overwrap labeled as Potassium Chloride Inj 10 mEq may contain flexible containers of Potassium Chloride Inj 20 mEq
Class II — Moderate risk. May cause temporary or reversible harm; serious harm unlikely.
Presence of Particulate Matter; stainless steel
Cause type: Particulate / foreign matter
Visible foreign particles - glass, metal, fibers or other material - found in the product. Particles can enter from equipment wear, containers or the process, and are dangerous in injectables. All particulate / foreign matter recalls.
0.9% Sodium Chloride Injection, USP in 1000 mL Single Dose Flexible Container, Hospira, Inc., Lake Forest, IL 60045 USA --- NDC# 0409-7983-09
Compare with the code on your package — it is the most precise check available.
Check, then ask. Class II means harm is possible but usually temporary or reversible. Find the lot number on your package; if it matches, ask your pharmacist about a replacement. Do not simply stop a prescribed medication on your own - the gap can be riskier than the recall. This recall is now terminated, which means the firm has finished removing the affected product; anything on pharmacy shelves today should be unaffected.
Labeling: Label Error on Declared Strength. Overwrap labeled as Potassium Chloride Inj 10 mEq may contain flexible containers of Potassium Chloride Inj 20 mEq
Labeling: Label Error on Declared Strength. Cases labeled POTASSIUM CHLORIDE 20 mEq, may contain flexible containers with overwrap mislabeled as 10 mEq. The correct dosage strength of 20 mEq is printed on the labeling affixed to the product flexible container.
Lack of assurance of sterility: Bags have the potential to leak in the flexible containers which may compromise sterility.
Presence of Particulate Matter: Particulate matter identified as fibers, hair, and proteinaceous material along with other particles, found in retain smples.
Presence of foreign substance: metallic razor blade was found in one bottle.
Presence of particulate matter
Presence of Particulate Matter: identified as polyethylene, which is consistent with the material used to manufacture the contain cap
Presence of Foreign Substance: Reports have been received of damaged StripPax packets containing silica gel desiccant potentially allowing the silica gel granules to make contact with Auryxia tablets in the bottle.