Succinylcholine Chloride Injection
Out-of-Specification (OOS) result during the 6-month stability testing; decreased preservative concentration.
Class III — Low risk. Unlikely to cause harm, but violates FDA regulations.
Labeling: Incorrect or Missing Lot and/or Exp Date: Potential for the lot number and/or expiration date to be faded or missing from the primary label on the glass vial.
Cause type: Labeling / mix-up
Wrong label, wrong strength, mixed-up products, or packaging errors. One of the most dangerous causes - you can end up taking the wrong drug or the wrong dose. All labeling / mix-up recalls.
Quelicin (Succinylcholine Chloride) Injection, USP 200 mg. (20 mg/mL), 10 mL Multiple-dose vial, packaged in 25 Unit vials per carton, Rx only, HOSPIRA, INC., LAKE FOREST, IL 60045 USA, NDC 0409-6629-02
Compare with the code on your package — it is the most precise check available.
Drug: Succinylcholine
From the FDA NDC directory, for the product code this recall names. Compare with the label on your package.
| Product | Strength | Form & route | Labeler | Type |
|---|---|---|---|---|
| Quelicin Succinylcholine Chloride NDC 00409-6629 |
20 mg/mL | Injection, Solution Intramuscular|intravenous |
Hospira, Inc. | Rx |
Low risk, still worth a check. Class III means the product is unlikely to cause harm but breaks an FDA rule (often labeling). If your lot matches, your pharmacy will normally swap it; there is no need for alarm.
Out-of-Specification (OOS) result during the 6-month stability testing; decreased preservative concentration.
Failed Impurities/Degradation Specifications: Out-of-Specification test results obtained for any individual unknown degradation impurity.
Lack of Assurance of Sterility
Lack of Assurance of Sterility
Lack of assurance of sterility:
Presence of Particulate Matter: human hair found within an internal sample syringe.
Lack of Assurance of Sterility: Complaints of broken tips on the ampules.
Discoloration: Firm received complaints of product discoloration and particulates.
Failed Stability Specifications: The recalled lots did not meet the specification for color and pH throughout shelf life.