Independent register of U.S. FDA drug recalls · updated Oct 10, 2026
RxRecalls Get alerts
Class II · Moderate risk Terminated Initiated Sep 27, 2012 (14 years ago)

Dr. Reddy's Quetiapine Fumarate Tablets

Class II — Moderate risk. May cause temporary or reversible harm; serious harm unlikely.

Why it was recalled

Failed USP Dissolution Test Requirements: During analysis of long term stability studies at 3 months time point, an OOS was reported for Quetiapine Fumarate Tablets, 25 mg.

Cause type: Dissolution failure

The tablet or capsule did not dissolve within specification. Dissolution controls how much drug the body absorbs; a failure can change the effective dose. All dissolution failure recalls.

What was recalled

Dr. Reddy's Quetiapine Fumarate Tablets, 25mg, Rx Only, 500 tablets. Mfd By: Dr. Reddy's Laboratories Limited, Bachepalli - 502 325, India NDC 55111-249-05

Affected NDC 55111-0249-05

Compare with the code on your package — it is the most precise check available.

Drug: Quetiapine Category: Mental Health Medication

Recalling firm
Dr. Reddy's Laboratories, Inc.
NDC code
55111-249-05
Origin
NJ, United States
Initiated by
Voluntary: Firm initiated
FDA recall number
D-059-2013 · FDA notice

Check, then ask. Class II means harm is possible but usually temporary or reversible. Find the lot number on your package; if it matches, ask your pharmacist about a replacement. Do not simply stop a prescribed medication on your own - the gap can be riskier than the recall. This recall is now terminated, which means the firm has finished removing the affected product; anything on pharmacy shelves today should be unaffected.

Other Quetiapine recalls

See all
Class III · Low risk

Quetiapine Fumarate Extended-Release Tablets

Labeling; Incorrect or Missing Package Insert: Product was packaged with the package insert for Quetiapine Fumarate Tablets not Quetiapine Fumarate Extended-Release Tablets.

Terminated Labeling / mix-up The Harvard Drug Group D-1002-2020
Class III · Low risk

Quetiapine Fumarate Extended-Release Tablets

Labeling; Incorrect or Missing Package Insert: Product was packaged with the package insert for Quetiapine Fumarate Tablets not Quetiapine Fumarate Extended-Release Tablets.

Terminated Labeling / mix-up The Harvard Drug Group D-1001-2020
Class III · Low risk

Quetiapine Fumarate Extended-Release Tablets

Labeling; Incorrect or Missing Package Insert: Product was packaged with the package insert for Quetiapine Fumarate Tablets not Quetiapine Fumarate Extended-Release Tablets.

Terminated Labeling / mix-up The Harvard Drug Group D-1000-2020
Class III · Low risk

Quetiapine Fumarate Extended-Release Tablets

Labeling; Incorrect or Missing Package Insert: Product was packaged with the package insert for Quetiapine Fumarate Tablets not Quetiapine Fumarate Extended-Release Tablets.

Terminated Labeling / mix-up The Harvard Drug Group D-0999-2020

Other recalls by Dr. Reddy's Laboratories, Inc.

All 2012 recalls
Class III · Low risk

Varenicline Tablets

Sub potent drug: during the 9-month stability test conducted, the assay value for the affected lot was below specification limit.

Ongoing Wrong potency / content Dr. Reddy's Laboratories, Inc. NDC 43598-908-56 D-0219-2026
Class II · Moderate risk

Omeprazole Delayed-release Capsules

Presence of foreign tablets/capsules: presence of foreign Divalproex Sodium Extended-Release 250mg tablet in a bottle of omeprazole capsules.

Ongoing Particulate / foreign matter Dr. Reddy's Laboratories, Inc. NDC 82009-022-10 D-0525-2025
Class I · High risk

Levetiracetam 0.75% in Sodium Chloride Injection 1

LABELING: LABEL MIX-UP: The infusion bag is incorrectly labeled as Levetiracetam in 0.82% Sodium Chloride Injection 500 mg/100 mL, while the aluminum overwrap packaging correctly identifies the product as Levetiracetam in 0.75% Sodium Chloride Injection 1,000 mg/100 mL.

Ongoing Labeling / mix-up Dr. Reddy's Laboratories, Inc. NDC 43598-636-52 D-0365-2025