Lorazepam 0.5 mg per 0.25 mL Oral Syringe
Defective Delivery System: Leakage observed after oral solution was repackaged into unit-dose syringes.
Class II — Moderate risk. May cause temporary or reversible harm; serious harm unlikely.
Failed Impurities/Degradation Specifications: An out-of-Specification for total related compounds
Cause type: Impurity / degradation
An impurity or degradation product above its limit - other than nitrosamines. Unexpected substances in a batch can make it unsafe or less effective, even when the active ingredient is present. All impurity / degradation recalls.
Lorazepam Injection, USP, 2 mg/mL, 25 x 1mL vials/carton, Rx Only, Manufactured by: Hikma Berkeley Heights, NJ 07922, NDC# 0641-6044-25
Compare with the code on your package — it is the most precise check available.
Drug: Lorazepam
From the FDA NDC directory, for the product code this recall names. Compare with the label on your package.
| Product | Strength | Form & route | Labeler | Type |
|---|---|---|---|---|
| Lorazepam NDC 00641-6044 |
2 mg/mL | Injection Intramuscular|intravenous |
Hikma Pharmaceuticals USA Inc. | Rx · CIV |
Check, then ask. Class II means harm is possible but usually temporary or reversible. Find the lot number on your package; if it matches, ask your pharmacist about a replacement. Do not simply stop a prescribed medication on your own - the gap can be riskier than the recall.
Defective Delivery System: Leakage observed after oral solution was repackaged into unit-dose syringes.
Failed impurities/degradation specifications and Sub-potent Drug: Out-of-specification results were obtained during routine stability testing for Assay and Impurities.
Failed impurities/degradation specifications and Sub-potent Drug: Out-of-specification results were obtained during routine stability testing for Assay and Impurities.
Failed impurities/degradation specifications and Sub-potent Drug: Out-of-specification results were obtained during routine stability testing for Assay and Impurities.
Failed Impurities/Degradation Specifications: Out-of-specification results for total related compounds observed during retain steting due to the elevated Related Compound-C.
Failed Impurities/Degradation Specifications: OOS result obtained for a process impurity, dicyclohexylurea (DCU).
This recall is being conducted due to out of specification assay results in a limited number of bottles that were stored on side.
Labeling: Label Mix-up: a bag of Dexmedetomidine HCl in 0.9% Sodium Chloride Injection was found inside an overwrap labeled Acetaminophen Injection 1,000 mg per 100 mL (10 mg/mL)
The filter included in the carton has an expiration date that has expired prior to the expiration date of the actual product lot.