fentaNYL Citrate
Labeling: Not Elsewhere Classified: Complaint received on 08/31/2026 regarding the discrepancy of the IV bag expiry (07/31/2026 and 11/30/2026) and the product expiry (12/09/2026).
Class II — Moderate risk. May cause temporary or reversible harm; serious harm unlikely.
Presence of Particulate matter: manufacturer recalled fentanyl API due to potential for glass particules
Cause type: Particulate / foreign matter
Visible foreign particles - glass, metal, fibers or other material - found in the product. Particles can enter from equipment wear, containers or the process, and are dangerous in injectables. All particulate / foreign matter recalls.
fentaNYL 200 mcg/100 mL (2 mcg/mL) BUPivacaine HCl 0.125% 125 mg/100 mL (1.25 mg/mL) in 0.9% Sodium Chloride Preservative Free, 100 mL in 150 Bag, Rx, QuVA Pharma 1075 West Park One Drive, Suite 100 Sugar Land, TX 77478 NDC 70092-1104-36
Compare with the code on your package — it is the most precise check available.
Drug: Fentanyl
Check, then ask. Class II means harm is possible but usually temporary or reversible. Find the lot number on your package; if it matches, ask your pharmacist about a replacement. Do not simply stop a prescribed medication on your own - the gap can be riskier than the recall. This recall is now terminated, which means the firm has finished removing the affected product; anything on pharmacy shelves today should be unaffected.
Labeling: Not Elsewhere Classified: Complaint received on 08/31/2026 regarding the discrepancy of the IV bag expiry (07/31/2026 and 11/30/2026) and the product expiry (12/09/2026).
Subpotent Drug
cGMP deviations.
cGMP deviations.
cGMP deviations.
Failed Impurities/Degradation Specifications
Presence of Particulate Matter
Lack of Assurance of Sterility
Lack of Assurance of Sterility