Enoxaparin Sodium Injection
Correct Labeled Product Mispack: Bags labeled for Enoxaparin Sodium Injection, 80 mg/0.8 mL, contained Enoxaparin Sodium Injection, 30 mg/0.3 mL
Class I — High risk. Reasonable probability of serious harm or death.
Labeling; Label Mixup; syringe barrels may contain markings for 100 mg/mL (corresponding to 100 mg/mL strength) instead of 150 mg/mL (corresponding to 120 mg/0.8mL strength)
Cause type: Labeling / mix-up
Wrong label, wrong strength, mixed-up products, or packaging errors. One of the most dangerous causes - you can end up taking the wrong drug or the wrong dose. All labeling / mix-up recalls.
Enoxaparin Sodium Injection, USP 120 mg/ 0.8 mL Single Dose Syringes with Automatic Safety Device For Subcutaneous Injection 10 x 0.8 mL Single Dose Syringes Rx Only,Manufactured by: Gland Pharma Ltd. Hyderabad, India Manufactured for: Apotex Corp. Weston, FL 33326 NDC 60505-0796-4 UPC 360505079543 (carton) NDC 60505-0796-0 UPC (01)10360505079602 (label)
Compare with the code on your package — it is the most precise check available.
Drug: Enoxaparin
Treat this as urgent. Class I means FDA judged there is a reasonable probability of serious harm. Find the lot number on your package; if it matches the recalled lots, do not take another dose before you have spoken to your pharmacist or prescriber - today, not next week.
Correct Labeled Product Mispack: Bags labeled for Enoxaparin Sodium Injection, 80 mg/0.8 mL, contained Enoxaparin Sodium Injection, 30 mg/0.3 mL
CGMP Deviations: Products were exposed to temperatures outside of the products labeled storage conditions.
Temperature Abuse; temperature excursion during shipping
CGMP Deviations: Intermittent exposure to temperature excursion during storage.
Labeling; Label Mixup; syringe barrels may containing markings for 150 mg/mL (corresponding to 120 mg/0.8mL strength) instead of 100 mg/mL markings (corresponding to 100 mg/mL strength)
Failed Dissolution Specifications; product failed to meet 24-month stability testing acceptance criteria
Defective container: defect in a batch of bottle caps, specifically involving dislodged or missing cap liners.
Lack of Assurance of Sterility
Lack of Assurance of Sterility; atypical weight loss due to improper bottle sealing leading to potential sterility concerns