Hydromorphone HCL PF
Labeling: Incorrect or Missing Lot and/or Exp Date
Class I — High risk. Reasonable probability of serious harm or death.
Superpotent (Single Ingredient) Drug: The prefilled cartridge unit has been found to be overfilled and contain more than the 1 mL labeled fill volume.
Cause type: Wrong potency / content
Sub- or super-potent product, or a failed content-uniformity / assay test. You may receive too little or too much active ingredient - a direct dosing risk. All wrong potency / content recalls.
HYDROmorphone HCl Injection, USP, 2 mg/mL, 1 mL fill in a 2.5 mL Carpuject prefilled cartridge unit, packaged in 10-count Carpujects per carton, Rx only, Hospira, Inc., Lake Forest, IL 60045, NDC 0409-1312-30, Barcode (01) 1 030409 131230 9 (carton), (01) 0 030409 131230 2 (cartridge unit).
Compare with the code on your package — it is the most precise check available.
Drug: Hydromorphone
From the FDA NDC directory, for the product code this recall names. Compare with the label on your package.
| Product | Strength | Form & route | Labeler | Type |
|---|---|---|---|---|
| Hydromorphone Hydrochloride NDC 00409-1312 |
2 mg/mL | Injection, Solution Intramuscular|intravenous|subcutaneous |
Hospira, Inc. | Rx · CII |
Treat this as urgent. Class I means FDA judged there is a reasonable probability of serious harm. Find the lot number on your package; if it matches the recalled lots, do not take another dose before you have spoken to your pharmacist or prescriber - today, not next week. This recall is now terminated, which means the firm has finished removing the affected product; anything on pharmacy shelves today should be unaffected.
Labeling: Incorrect or Missing Lot and/or Exp Date
Superpotent Drug: Assay/potency result for hydromorphone HCl in the compounded stability lot was higher than specification..
Lack of Assurance of Sterility
Lack of Assurance of Sterility
Lack of Assurance of Sterility
Presence of Particulate Matter: human hair found within an internal sample syringe.
Lack of Assurance of Sterility: Complaints of broken tips on the ampules.
Discoloration: Firm received complaints of product discoloration and particulates.
Failed Stability Specifications: The recalled lots did not meet the specification for color and pH throughout shelf life.
Free recall alerts
Tell us what you take. When FDA posts a recall announcement or classifies a recall for one of your medications, we email you in plain English, with what to check. No account needed.