Ezetimibe and Simvastatin Tablets
Failed Impurities/Degradation Specifications: Out of Specification (OOS) for related substances test for Anhydro Simvastatin at the 06-month time point during long-term stability study.
Class II — Moderate risk. May cause temporary or reversible harm; serious harm unlikely.
Failed Excipient Specifications; product manufactured using an excipient found to be OOS for conductivity
Cause type: Failed specification
A physical or chemical test other than potency, dissolution, impurity or stability failed - pH, viscosity, appearance, tablet integrity, fill volume. A product outside its own specification may not perform as designed, even if the active ingredient is present. All failed specification recalls.
Dr. Reddy's Ezetimibe and Simvastatin Tablets, 10 mg/10 mg, a) 90 count (NDC 43598-742-90) and b) 1000 count (NDC 43598-742-10) bottles, Rx only, Manufactured by: Dr. Reddy's Laboratories LA LLC, Shreveport, LA 71106, USA, Distributed by: Dr. Reddy's Laboratories Inc., Princeton, NJ 08540 USA, , packaged in bottles.
Compare with the code on your package — it is the most precise check available.
Drug: Simvastatin Category: Cholesterol Medication
From the FDA NDC directory, for the product code this recall names. Compare with the label on your package.
| Product | Strength | Form & route | Labeler | Type |
|---|---|---|---|---|
| Ezetimibe and Simvastatin NDC 43598-0742 |
EZETIMIBE 10 mg/1; SIMVASTATIN 10 mg/1 | Tablet Oral |
Dr.Reddys Laboratories Inc | Rx |
Check, then ask. Class II means harm is possible but usually temporary or reversible. Find the lot number on your package; if it matches, ask your pharmacist about a replacement. Do not simply stop a prescribed medication on your own - the gap can be riskier than the recall. This recall is now terminated, which means the firm has finished removing the affected product; anything on pharmacy shelves today should be unaffected.
Failed Impurities/Degradation Specifications: Out of Specification (OOS) for related substances test for Anhydro Simvastatin at the 06-month time point during long-term stability study.
CGMP deviations.
CGMP deviations.
CGMP deviations.
cGMP Deviations for the manufacturing Firm (Accord Healthcare) after their inspection.
Sub potent drug: during the 9-month stability test conducted, the assay value for the affected lot was below specification limit.
Out-of-Specification (OOS) result during the 6-month stability testing; decreased preservative concentration.
Presence of foreign tablets/capsules: presence of foreign Divalproex Sodium Extended-Release 250mg tablet in a bottle of omeprazole capsules.
LABELING: LABEL MIX-UP: The infusion bag is incorrectly labeled as Levetiracetam in 0.82% Sodium Chloride Injection 500 mg/100 mL, while the aluminum overwrap packaging correctly identifies the product as Levetiracetam in 0.75% Sodium Chloride Injection 1,000 mg/100 mL.
Free recall alerts
Tell us what you take. When FDA posts a recall announcement or classifies a recall for one of your medications, we email you in plain English, with what to check. No account needed.