Oxycodone and Acetaminophen CII Tablets USP
Failed Tablet/Capsule Specification: There is a potential for the imprint to be missing on tablets.
Class II — Moderate risk. May cause temporary or reversible harm; serious harm unlikely.
Superpotent Drug: Qualitest Pharmaceuticals is initiating a recall of three flavors of Acetaminophen Oral Suspension Liquid 160mg/5mL for failure of the product assay at the 12 month timepoint.
Cause type: Wrong potency / content
Sub- or super-potent product, or a failed content-uniformity / assay test. You may receive too little or too much active ingredient - a direct dosing risk. All wrong potency / content recalls.
CHILDREN'S Q-PAP, Acetaminophen, ORAL SUSPENSION, CHERRY FLAVOR, Active ingredient (in each 5 mL = 1 tsp) Acetaminophen USP 160 mg, 4 FL OZ (118 mL), Made in the USA for Qualitest Pharmaceuticals, Huntsville, AL 35811, NDC 0603-0842-54, OTC
Compare with the code on your package — it is the most precise check available.
Drug: Acetaminophen Category: Pain Relief & OTC Medication
Check, then ask. Class II means harm is possible but usually temporary or reversible. Find the lot number on your package; if it matches, ask your pharmacist about a replacement. Do not simply stop a prescribed medication on your own - the gap can be riskier than the recall. This recall is now terminated, which means the firm has finished removing the affected product; anything on pharmacy shelves today should be unaffected.
Failed Tablet/Capsule Specification: There is a potential for the imprint to be missing on tablets.
Failed Tablet/Capsule Specification: There is a potential for the imprint to be missing on tablets.
Defective Container
Labeling: Label Mix-up. This issue affects the outer box labeling only. The box incorrectly states the ingredients Acetaminophen 500mg and Caffeine 65mg. The inner pouch correctly states the ingredients are Aspirin (NSAID)*500mg and Caffeine 32.5mg.
Discoloration
Failed Tablet/Capsule Specifications; report of oversized and discolored tablets
Failed Tablet/Capsule Specifications; The identification codes on some tablets may be unreadable
Failed Dissolution Specifications: During routine stability testing at the 12 month time point, one product lot was found to be out of specification for dissolution.
Failed Impurities/Degradation Specifications: A stability lot was out of specification for a known impurity at the 8 month Controlled Room Temperature stability time-point.